Interface Units

CAN Interface Units
Analogue or Pt1000

The interface unit allows the connection of 16 Analogue or Pt1000 temperature sensor inputs or a combination of both (software configurable) and transmits them over CAN. Using CAN configuration the user can select which type of input is required for each channel and set the unit CAN address. Each sensor connector has a fused (re-settable) 12V and 5V supply. The unit has a sync input, when triggered it forces simultaneous transmission of all 16 channels.

Unit supply voltage:8V to 16 Vdc
Inputs:16 x Analogue or Pt1000
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity

CAN Interface Units
Digital Speed/Switch/Analogue/K-Type Inputs

The interface unit allows the connection of 4 x digital/switch inputs, 10 x analogue or Pt1000 inputs and 3 x K-Type thermocouple inputs and transmits them over CAN. Using CAN configuration the user can select the unit CAN address. The unit has a sync input, when triggered it forces simultaneous transmission of all channel.

Unit supply voltage:8V to 16 Vdc
Inputs:4 x Digital/Speed, 10 x Analogue, 3 x K-Type
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity

CAN Interface Units
K-Type Thermocouple

The interface unit allows the connection of 12 K-Type temperature sensors inputs and transmits them over CAN. Using CAN configuration the user can select the unit CAN address. The unit has a sync input, when triggered it forces simultaneous transmission of all 12 channel.

Unit supply voltage:8V to 16 Vdc
Inputs:12 x K-Type Thermocouples
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity

CAN Interface Units
5 Wire LVDT

This interface unit allows the connection of 6 LVDT sensors with 5 wire configuration and transmits them over CAN. Using CAN configuration, the user can select the unit CAN address and LVDT excitation frequency. The unit has a sync input, when triggered it forces simultaneous transmission of all 6 channels.

Unit supply voltage:8V to 16 Vdc
Inputs:6 x 5 wire LVDT
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity