Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the cookie-law-info domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the rocket domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /var/www/wp-includes/functions.php on line 6114
Products - Interface Units - Elite Sensors Ltd

Interface Units

CAN Interface Units
Analogue or Pt1000

The interface unit allows the connection of 16 Analogue or Pt1000 temperature sensor inputs or a combination of both (software configurable) and transmits them over CAN. Using CAN configuration the user can select which type of input is required for each channel and set the unit CAN address. Each sensor connector has a fused (re-settable) 12V and 5V supply. The unit has a sync input, when triggered it forces simultaneous transmission of all 16 channels.

Unit supply voltage:8V to 16 Vdc
Inputs:16 x Analogue or Pt1000
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity

CAN Interface Units
Digital Speed/Switch/Analogue/K-Type Inputs

The interface unit allows the connection of 4 x digital/switch inputs, 10 x analogue or Pt1000 inputs and 3 x K-Type thermocouple inputs and transmits them over CAN. Using CAN configuration the user can select the unit CAN address. The unit has a sync input, when triggered it forces simultaneous transmission of all channel.

Unit supply voltage:8V to 16 Vdc
Inputs:4 x Digital/Speed, 10 x Analogue, 3 x K-Type
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity

CAN Interface Units
K-Type Thermocouple

The interface unit allows the connection of 12 K-Type temperature sensors inputs and transmits them over CAN. Using CAN configuration the user can select the unit CAN address. The unit has a sync input, when triggered it forces simultaneous transmission of all 12 channel.

Unit supply voltage:8V to 16 Vdc
Inputs:12 x K-Type Thermocouples
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity

CAN Interface Units
5 Wire LVDT

This interface unit allows the connection of 6 LVDT sensors with 5 wire configuration and transmits them over CAN. Using CAN configuration, the user can select the unit CAN address and LVDT excitation frequency. The unit has a sync input, when triggered it forces simultaneous transmission of all 6 channels.

Unit supply voltage:8V to 16 Vdc
Inputs:6 x 5 wire LVDT
Output:CAN
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Increased connectivity

1 Channel PT1000 to Analogue Interface Units

This interface unit allows the connection of 1 x Pt1000 temperature sensor input and converts it to an analogue signal. The interface is fully potted to offer high vibration resistance.

Unit supply voltage:8V to 16 Vdc
Inputs:1 x PT1000
Output ranges*:-55°C to +155°C
-100°C to +100°C
Output:0V to 5V
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Connection of PT1000 when not supported by the ECU.

*Other ranges available on request.

1 Channel K-Type thermocouple to Analogue Interface Units

This interface unit allows the connection of 1 x K-Type thermocouple and converts it into an analogue signal. The interface is fully potted to offer high vibration resistance.

Unit supply voltage:5 Vdc
Inputs:1 x K-type
Output ranges*:300°C to +1260°C
Output:0V to 5V
Operating temperature:-10°C to +125°C
Vibration:20g Sinusoidal 50 to 2500Hz
Typical applications:Connection of K-types when not supported by the ECU.

*Other ranges available on request.